# # tp-fancontrol configuration file # # Options: # enabled = [True / False] # override_profile = [True / False] # hysteresis = [hysteresis temperature difference] # interval_speed = [fan speed for interval mode] # interval_duration = [duration of fan rotation in interval mode] # interval_delay = [delay between fan rotations in interval mode] # # Trigger point syntax: # [sensor-id]. [human readable sensor name] = [temperature]:[fan level] ... # [fan level] = 0: fan off # [fan level] = 1: interval cooling mode # [fan level] = 255: hardware controlled cooling mode # default rule is used for all unspecified sensors # # override_profile = True has to be specified before profile parameters # or trigger points are changed in the configuration file. # tpfand may regenerate this file at any time. Custom comments will be lost. # enabled = True override_profile = True 0. CPU = 0:0 56:4 61:5 63:6 66:8 68:256 1. APS = 0:0 51:2 53:255 2. PCM = 0:0 50:255 3. GPU = 0:0 61:4 64:5 68:6 70:256 4. BAT1 = 0:0 50:256 5. Sensor 5 = 0:255 6. BAT2 = 0:0 50:255 7. Sensor 7 = 0:255 8. BUS = 0:0 55:4 58:255 9. ??? = 0:0 57:5 61:6 63:255 10. PWR = 0:0 57:5 60:6 63:8 65:255 11. Sensor 11 = 0:255 12. Sensor 12 = 0:255 13. Sensor 13 = 0:255 14. Sensor 14 = 0:255 15. Sensor 15 = 0:255 hysteresis = 3 interval_speed = 2 interval_duration = 13.000000 interval_delay = 700.000000